Unidades terminales VAV

Produktfinder

layer

Type TVM

 

VAV dual duct terminal units for dual duct systems with variable volume flows in buildings with demanding acoustic requirements

  • Individual temperature control for each room or zone
  • Highly effective integral attenuator
  • Electronic control components for different applications (Compact and Universal)
  • Suitable for airflow velocities up to 13 m/s
  • Closed blade air leakage to EN 1751, class 4
  • Casing air leakage to EN 1751, class A


Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TS for the reduction of air-regenerated noise

leer más

layer

Type TA-Silenzio

 

Rectangular VAV terminal units for the extract air control in buildings with variable air volume systems, demanding acoustic requirements and low airflow velocities

  • Highly effective integral attenuator
  • Optimised for airflow velocities of 0.7 – 6 m/s
  • High control accuracy even in case of unfavourable upstream conditions
  • Compact construction with rectangular connections on both ends
  • Electronic control components for different applications (Easy, Compact and Universal)
  • Closed blade air leakage to EN 1751, class 4
  • Casing air leakage to EN 1751, class B


Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TS for the reduction of air-regenerated noise

leer más

layer

Type TVRK

 

Plastic circular VAV terminal units for aggressive extract air in variable air volume systems

  • Casing and damper blade made of flame-resistant polypropylene
  • Slide-out differential pressure sensor allows for easy cleaning
  • Suitable for the control of volume flow rate, room pressure or duct pressure
  • Electronic control components for different applications (Universal and LABCONTROL)
  • Suitable for airflow velocities up to 13 m/s
  • Closed blade air leakage to EN 1751, class 3
  • Casing air leakage to EN 1751, class B


Optional equipment and accessories

  • With flanges on both ends
  • Matching flanges for both ends
  • Plastic secondary silencer Type CAK for the reduction of air-regenerated noise

leer más

layer

Type TVA

 

VAV terminal units for the extract air control in buildings with variable air volume systems and demanding acoustic requirements

  • Highly effective integral attenuator
  • Box style construction for the reduction of the airflow velocity
  • Electronic control components for different applications (Easy, Compact, Universal, and LABCONTROL)
  • Suitable for airflow velocities up to 13 m/s
  • Closed blade air leakage to EN 1751, class 4
  • Casing air leakage to EN 1751, class A


Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TS for the reduction of air-regenerated noise

leer más

layer

Type LVC

 

Circular VAV terminal units for supply air and extract air systems with variable volume flows, low airflow velocities and low duct pressures

  • New measurement principle, optimised for airflow velocities from 0.6 to 6 m/s
  • High control accuracy even in case of unfavourable upstream conditions
  • Electronic control components for different applications (Easy, Compact)
  • Easy handling due to innovative control technique
  • Casing length of only 310 mm for all nominal sizes
  • Any installation orientation
  • Closed blade air leakage to EN 1751, up to class 2
  • Casing air leakage to EN 1751, class C


Optional equipment and accessories

  • Secondary silencer Type CA, CS or CF for the reduction of air-regenerated noise
  • Hot water heat exchanger Type WL and electric air heater Type EL for reheating the airflow

leer más

layer

Type TVR-Ex

 

Circular VAV terminal units for variable air volume systems, approved and certified for potentially explosive atmospheres (ATEX)

  • ATEX-compliant construction and parts
  • Approved for all gases, mists and vapours in zones 1 and 2, with electronic control additionally for dusts in zones 21 and 22
  • Suitable for the control of supply or extract air as well as for differential pressure control
  • Electronic or pneumatic control components
  • Closed blade air leakage to EN 1751, class 4
  • Casing air leakage to EN 1751, class C


Optional equipment and accessories

  • Spring return actuator
  • Auxiliary switch with adjustable switching points for capturing the end positions

leer más

layer

Type TVT

 

Rectangular VAV terminal units for standard applications regarding the supply air or extract air control in variable air volume systems where low-leakage shut-off is required

  • For volume flow rate ranges up to 21,000 m³/h or 5,800 l/s
  • Suitable for the control of volume flow rate, room pressure or duct pressure
  • Electronic control components for different applications (Easy, Compact, Universal, and LABCONTROL)
  • High control accuracy
  • Suitable for airflow velocities up to 10 m/s
  • Closed blade air leakage to EN 1751, class 3
  • Casing air leakage to EN 1751, class C


Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TX for the reduction of air-regenerated noise
  • Hot water heat exchanger Type WT for reheating the airflow

leer más

layer

Type TVZ

 

VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

  • Highly effective integral attenuator
  • Box style construction for the reduction of the airflow velocity
  • Electronic control components for different applications (Easy, Compact, Universal, and LABCONTROL)
  • Suitable for airflow velocities up to 13 m/s
  • Closed blade air leakage to EN 1751, class 4
  • Casing air leakage to EN 1751, class A


Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TS for the reduction of air-regenerated noise
  • Hot water heat exchanger Type WT for reheating the airflow

leer más

Next" data-pagination-prev="Prev" data-pagination-source="product-finder-results">

Product Finder

layer

Type TVM

 

VAV dual duct terminal units for dual duct systems with variable volume flows in buildings with demanding acoustic requirements

  • Individual temperature control for each room or zone
  • Highly effective integral attenuator
  • Electronic control components for different applications (Compact and Universal)
  • Suitable for airflow velocities up to 13 m/s
  • Closed blade air leakage to EN 1751, class 4
  • Casing air leakage to EN 1751, class A


Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TS for the reduction of air-regenerated noise

leer más

layer

Type TA-Silenzio

 

Rectangular VAV terminal units for the extract air control in buildings with variable air volume systems, demanding acoustic requirements and low airflow velocities

  • Highly effective integral attenuator
  • Optimised for airflow velocities of 0.7 – 6 m/s
  • High control accuracy even in case of unfavourable upstream conditions
  • Compact construction with rectangular connections on both ends
  • Electronic control components for different applications (Easy, Compact and Universal)
  • Closed blade air leakage to EN 1751, class 4
  • Casing air leakage to EN 1751, class B


Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TS for the reduction of air-regenerated noise

leer más

layer

Type TVRK

 

Plastic circular VAV terminal units for aggressive extract air in variable air volume systems

  • Casing and damper blade made of flame-resistant polypropylene
  • Slide-out differential pressure sensor allows for easy cleaning
  • Suitable for the control of volume flow rate, room pressure or duct pressure
  • Electronic control components for different applications (Universal and LABCONTROL)
  • Suitable for airflow velocities up to 13 m/s
  • Closed blade air leakage to EN 1751, class 3
  • Casing air leakage to EN 1751, class B


Optional equipment and accessories

  • With flanges on both ends
  • Matching flanges for both ends
  • Plastic secondary silencer Type CAK for the reduction of air-regenerated noise

leer más

layer

Type TVA

 

VAV terminal units for the extract air control in buildings with variable air volume systems and demanding acoustic requirements

  • Highly effective integral attenuator
  • Box style construction for the reduction of the airflow velocity
  • Electronic control components for different applications (Easy, Compact, Universal, and LABCONTROL)
  • Suitable for airflow velocities up to 13 m/s
  • Closed blade air leakage to EN 1751, class 4
  • Casing air leakage to EN 1751, class A


Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TS for the reduction of air-regenerated noise

leer más

layer

Type LVC

 

Circular VAV terminal units for supply air and extract air systems with variable volume flows, low airflow velocities and low duct pressures

  • New measurement principle, optimised for airflow velocities from 0.6 to 6 m/s
  • High control accuracy even in case of unfavourable upstream conditions
  • Electronic control components for different applications (Easy, Compact)
  • Easy handling due to innovative control technique
  • Casing length of only 310 mm for all nominal sizes
  • Any installation orientation
  • Closed blade air leakage to EN 1751, up to class 2
  • Casing air leakage to EN 1751, class C


Optional equipment and accessories

  • Secondary silencer Type CA, CS or CF for the reduction of air-regenerated noise
  • Hot water heat exchanger Type WL and electric air heater Type EL for reheating the airflow

leer más

layer

Type TVR-Ex

 

Circular VAV terminal units for variable air volume systems, approved and certified for potentially explosive atmospheres (ATEX)

  • ATEX-compliant construction and parts
  • Approved for all gases, mists and vapours in zones 1 and 2, with electronic control additionally for dusts in zones 21 and 22
  • Suitable for the control of supply or extract air as well as for differential pressure control
  • Electronic or pneumatic control components
  • Closed blade air leakage to EN 1751, class 4
  • Casing air leakage to EN 1751, class C


Optional equipment and accessories

  • Spring return actuator
  • Auxiliary switch with adjustable switching points for capturing the end positions

leer más

layer

Type TVT

 

Rectangular VAV terminal units for standard applications regarding the supply air or extract air control in variable air volume systems where low-leakage shut-off is required

  • For volume flow rate ranges up to 21,000 m³/h or 5,800 l/s
  • Suitable for the control of volume flow rate, room pressure or duct pressure
  • Electronic control components for different applications (Easy, Compact, Universal, and LABCONTROL)
  • High control accuracy
  • Suitable for airflow velocities up to 10 m/s
  • Closed blade air leakage to EN 1751, class 3
  • Casing air leakage to EN 1751, class C


Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TX for the reduction of air-regenerated noise
  • Hot water heat exchanger Type WT for reheating the airflow

leer más

layer

Type TVZ

 

VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

  • Highly effective integral attenuator
  • Box style construction for the reduction of the airflow velocity
  • Electronic control components for different applications (Easy, Compact, Universal, and LABCONTROL)
  • Suitable for airflow velocities up to 13 m/s
  • Closed blade air leakage to EN 1751, class 4
  • Casing air leakage to EN 1751, class A


Optional equipment and accessories

  • Acoustic cladding for the reduction of case-radiated noise
  • Secondary silencer Type TS for the reduction of air-regenerated noise
  • Hot water heat exchanger Type WT for reheating the airflow

leer más

Please select your disired product properties:
Next" data-pagination-prev="Prev" data-pagination-source="product-finder-results">

Compartir

Recomendar

Recomendar el contenido de esta página, mandar por mail.

Los campos marcados con un (*) sin imprescindibles de cumplimentar

Compartir

Gracias por su recomendación!

Su recomendación ha sido enviada y llegará a su destino en breve.

Contacto

Estamos aquí para atenderles

Visual contact Visual contact

Please specify your message and type of request.
Tel.: +54 (11) 4233 5676

Los campos marcados con un (*) sin imprescindibles de cumplimentar

Contacto

Gracias por su mensaje.

Visual contact Visual contact

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +54 (11) 4233 5676

Contacto

Estamos aquí para atenderles

Visual contact Visual contact

Please specify your message and type of request.
Tel.: +54 (11) 4233 5676

Archivo adjunto (Max. 10MB)

Los campos marcados con un (*) sin imprescindibles de cumplimentar

Contacto

Gracias por su mensaje.

Visual contact Visual contact

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +54 (11) 4233 5676